Batch function tutorial

If you have a controller with the totalizer feature, you have the ability to set a batch fill. This allows you to set a specific total volume and a setpoint at the same time. Whether controlling flow or pressure, the device will hit the setpoint and automatically stop flow once the given total volume is achieved.

The batch function adds versatile batch processing to Alicat’s optional integrated flow totalizer for its gas mass flow controllers and liquid flow controllers. Users may dispense gas or liquid volumes at their desired flow rates by means of independently controlled batch values and flow rate setpoints. One-touch resetting provides easy duplication of batches via the flow controller’s front touch panel. Full batch control and totalizer data are also accessible via RS-232 digital communications.

Video tutorial

Video transcript

How do you dispense fluids in batches?

Alicat’s new precision dispensing package adds batch processing to gas or liquid flow controllers equipped with our totalizer option.

First set your batch volume (bottom left button). Then set your desired flow rate (top middle button). Flow stops as soon as the batch completes. Simply press reset (bottom middle button) to start your next batch.

Our fast, precision control valves ensure that dispensed volumes are consistent and repeatable.

Industrial reliability with repeatable precision. Brought to you by Alicat, the fastest flow controller company in the world.

Step-by-step instructions (front panel)

  1. First, set your desired batch volume. To do this, press the bottom left button, labeled “BATCH”, on the front panel display.
  2. Once in the batch function, enter your desired batch volume by using the top right button, labeled “SELECT DIGIT”, to select different digits of the batch volume and the top left and middle buttons, labeled “UP” and “DOWN” respectively, to increase or decrease the batch volume.
  3. To confirm your desired batch volume, press the “SET” button, located on the bottom right of the display panel.
  4. Next, set your desired flowrate using the setpoint function by pressing the top middle button on the front panel display, labeled “SETPT”.
  5. Once in the setpoint function, enter your desired flowrate by using the top right button, labeled “SELECT DIGIT”, to select different digits of the flowrate and the top left and middle buttons, labeled “UP” and “DOWN” respectively, to increase or decrease the flowrate.
  6. To confirm your desired flowrate, press the “SET” button, located on the bottom right of the display panel.
  7. The batch will then begin with the fluid dispensing at your desired flowrate and to your desired volume. Flow will stop as soon at the batch is completed.
  8. To start your next batch using the same parameters, simply press the reset button, which is the bottom middle button on the front panel display.

FastTrack Ordering

M/MC mass flow meters and controllers that ship in just 3-5 business days.
CALIBRATION
Standard or High Accuracy
DISPLAY
Monochrome, Color, or None
PROTOCOL
Analog, RS-232, RS-485, or Modbus RTU
CONNECTOR
MD8, Locking Industrial, DB9M, DB15
FITTINGS
NPT

METER RANGES

2 SCCM - 500SLPM

CONTROLLER RANGES

2 SCCM - 100SLPM

Service and Support

Whether it is time for your instrument’s annual recalibration or your instrument needs a repair or upgrade,
you can fill out the Service Request Form below, email us, call us, or start a live chat session to get the service process started.