M Series Meter
For most gas measurement
most versatile
- 0.5 SCCM – 10,000 SLPM options
- 11.5 – 160 PSIA operating
- Accuracy as good as ± 0.5% of reading
- ± (0.1% of reading + 0.02% of full scale) repeatability
Spec Sheets
MQ Series Meter
Measure flow rates at higher pressures
Highest pressure rating
- 10 SCCM – 10,000 SLPM options
- 11.5 – 320 PSIA operating
- Accuracy as good as ± 0.6% of reading or ±0.1% of full scale, whichever is greater
- ± 0.1% of full scale repeatability
Spec Sheets
MS Series Meter
For a wider range of gases
Corrosion-Resistant Wetted materials
- 130 gases, including corrosives
- 0.5 SCCM – 10,000 SLPM
- 11.5 – 160 PSIA
- ± 0.4% of reading and ± 0.2% of full scale accuracy
Spec Sheets
BIO Series Meter
Measure gases into and out of bioreactors + fermenters
ASME BPE compliant
-
Also uses laminar differential pressure mass flow meter technology
- Long-term stability
- Robust, compliant materials including USP Class VI or USPVI elastomers
- Designed for scalability (10,000:1 operating range)
Spec Sheets
Available Variants
MW Series Meter
Low pressure drop laminar DP mass flow meters
Build Options for Laminar Differential Pressure Mass Flow Meters
Communication Protocols
RS-232 Serial (default)
RS-485 Serial
Analog (4-20 mA, 0-10 Vdc, 0-5 Vdc, or 1-5 Vdc)
Modbus RTU (over RS-232 or RS-485)
Modbus TCP/IP
DeviceNet
EtherCAT
EtherNet/IP
PROFIBUS
PROFINET
IO-Link
RS-485 Serial
Analog (4-20 mA, 0-10 Vdc, 0-5 Vdc, or 1-5 Vdc)
Modbus RTU (over RS-232 or RS-485)
Modbus TCP/IP
DeviceNet
EtherCAT
EtherNet/IP
PROFIBUS
PROFINET
IO-Link
Process Connections
Ingress Protection
Hazardous Environment Ratings
CSA Class 1 Div 2, ATEX Class 1 Zone 2; uses Legacy – 8v firmware (2020) manual
For explosive environments, see IS-Max Series
For explosive environments, see IS-Max Series
Humid Gases
Relative humidity compensation
Measurement Technology
Laminar differential pressure (laminar DP) flow sensing with temperature and pressure correction.
FastTrack Ordering
Mass flow instruments that ship in just 3-5 business days.
CALIBRATION
Standard or High Accuracy
DISPLAY
Monochrome, Color, or None
PROTOCOL
Analog, RS-232, RS-485, Modbus RTU, or PROFIBUS
CONNECTOR
MD8, Locking Industrial, DB9M, DB15
FITTINGS
NPT
METER RANGES
2 SCCM - 500 SLPM
CONTROLLER RANGES
2 SCCM - 100 SLPM
Ready for the final details?
Each product is made-to-order. Alicat’s Applications Engineers are ready to provide expertise and discuss custom options, ensuring the best fit for your needs.
Downloads
Manuals
M Series Operating Manual Legacy – 8v firmware (2020) –Use this for CSA Class 1 Div2 or ATEX Class 1 Zone 2
Brochures
Software & Utilities
Call Us
+1 (888) 290-6060
service@alicat.com
Live Chat
Ask us a question
Help Near You
Find a local representative
Self Help
Technical documentation